Temporary climate control for New York & New England info@hcdne.com Call 518-419-8688

Serving New York & New England

Temporary heating, cooling & drying for construction and industry

Indirect heat, dehumidification, portable cooling, ground thaw, and building enclosures. Applied Structural Drying that protects finishes and keeps your project on schedule through every season.

Or call us directly: 518-419-8688

Heaters to 6,000,000 BTUNatural gas, oil, propane & electric
Cooling to 25 tonsPortable air conditioners
30 gal/day dehumidifiersWater removal per unit
Code-compliant enclosuresNFPA 705 Method II & BFD IX-1
Indirect heater exhaust vented through the wall of a building in winter, keeping combustion outside
Combustion exhaust vented outside a jobsite in winter. The flame and its byproducts never enter the building.

Why indirect heat

The flame stays outside. Only dry heat comes in.

  • No open flame in your space. Combustion happens in a sealed chamber and vents outdoors.
  • No added moisture. Open-flame make-up air heating adds water vapor to the building. Indirect heat adds none.
  • No combustion CO₂ indoors. Cleaner air for your crews and your concrete.
  • About half the fuel. Make-up air systems burn roughly twice as much fuel while pressurizing the space.
Indirect Heat vs. Make-Up Air

Recent work

On jobsites across the Northeast

Heat Wagon indirect heater running inside a building during interior framing
Indirect heat during interior build-out
Campo Equipment Blaze 400 heaters with exhaust ducted out of a warehouse
Heaters ducted and vented to the exterior
Multi-story building wrapped in flame-retardant enclosure sheeting for winter work
Full building enclosure for winter work
6,000,000BTU max heater size
25 tonsMax portable AC size
30 gal/dayWater removal per dehumidifier
10,000 sq ftGround thaw per unit

Trusted equipment

Equipment from the industry's leading manufacturers

Heat Wagon
L.B. White
Flagro
Frost Fighter
KwiKool portable cooling systems
Dryair
Dri-Eaz
Campo Equipment
Strong Man Safety Products

We repair and service all manufacturers' equipment, not just the brands we carry.

Service area

Proudly serving the Northeast

We provide temporary heating, cooling, and dehumidification throughout New York and New England. No matter the size of the project, Heat Cool Dry delivers expert climate control across the region.

New YorkNew Jersey PennsylvaniaMassachusetts ConnecticutRhode Island VermontNew Hampshire

Get started

Request a quote

Tell us about the project and we will size the equipment and provide fuel consumption and heat requirement estimates from our heat loss program.

Prefer to talk it through? Call 518-419-8688.

Common questions

Frequently asked questions

What is Applied Structural Drying (ASD)? +

Applied Structural Drying is a method of controlling temperature and humidity so a building dries as fast as possible while protecting finishes. During heat season we use indirect heat and dehumidification to manage moisture in the space. It is the most efficient way to heat a building and it improves productivity during finishes.

What is the difference between indirect heat and make-up air? +

With indirect-fired heating, combustion happens outside the occupied space and only clean, dry heat is delivered inside, so no water vapor or CO2 is added to the building. Make-up air heating burns fuel with an open flame inside the space, which introduces large amounts of water vapor and CO2 and burns roughly twice as much fuel while pressurizing the space.

How much water vapor and CO2 does temporary heating add to a building? +

Burning 11 gallons of propane through a make-up air heater (about 1,000,000 BTU) generates roughly 22 gallons of water vapor and 135 pounds of CO2 inside the space. Burning 10 therms of natural gas in an open-flame heater (about 1,000,000 BTU) produces roughly 11 gallons of water vapor and 135 pounds of CO2. Indirect-fired heating adds none of that moisture or CO2 to the interior.

What size equipment can I rent? +

We rent natural gas, oil, propane, and electric heaters up to 6,000,000 BTU, portable air conditioners up to 25 tons, and dehumidifiers that remove up to 30 gallons of water per day per unit. Ground thaw units can thaw up to 10,000 square feet each.

Do your building enclosures meet fire codes? +

Yes. Our weather protection and containment enclosures meet NFPA 705 Method II and Boston Fire Code BFD IX-1.

What areas does Heat Cool Dry serve? +

We provide temporary heating, cooling, and dehumidification throughout New York, New Jersey, Pennsylvania, Massachusetts, Connecticut, Rhode Island, Vermont, and New Hampshire.

What types of projects do you support? +

We support construction sites, industrial facilities, data centers, and distribution centers with temperature control, humidity control, ground thaw, and enclosures that keep projects on schedule through every season.

Do you service equipment from other manufacturers? +

Yes. We run equipment from manufacturers including Heat Wagon, L.B. White, Flagro, Frost Fighter, KwiKool, Dryair, Dri-Eaz, Campo Equipment, and Strong Man Safety Products, and we repair and service all manufacturers' equipment.