Temporary climate control for New York & New England info@hcdne.com Call 518-419-8688

What ASD is

Control temperature and humidity together, and the building dries itself

Applied Structural Drying (ASD) manages heat and moisture as one system. During heat season, we control the humidity in your building with indirect heat and dehumidification. It is the most efficient way to heat the building, and it directly improves productivity during finishes.

The alternative most sites default to is make-up air (MUA) heating: open-flame burners that push heated outside air into the space. That method introduces huge amounts of water vapor and CO₂ from combustion directly into your building, and burns roughly twice as much fuel while pressurizing the space.

Extech meter showing 2.6 percent relative humidity at 171 degrees Fahrenheit heater discharge
Supply air measured at a heater discharge: 2.6% RH at 171°F. Dry heat like this pulls moisture out of the structure.

The numbers

What each heating method puts into your building

Every heating method delivers BTUs. The difference is what comes along with them. Per 1,000,000 BTU delivered:

Heating methodWater vapor addedCO₂ added
Make-up air, propane
11 gallons burned, open flame
22 gallons135 lb
Make-up air, natural gas
10 therms burned, open flame
11 gallons135 lb
Indirect heat (ASD)
Combustion sealed and vented outside
0 gallons0 lb

Make-up air systems also burn roughly twice the fuel of indirect heat while pressurizing the space.

Heater exhaust pipes venting combustion outside a building in the snow
With indirect heat, this is where the combustion goes: outside.

The payoff

Nine hours of work in an eight-hour shift

When temperature and relative humidity are held in the right range, drywall, paint, and flooring dry on schedule instead of holding up the trades behind them. For every trade affected by moisture, we will give you nine hours worth of work in an eight-hour time period.

Drier conditions also mean cleaner finishes: fewer failed adhesion tests, less rework, and materials performing the way their spec sheets assume.

Set Up Drying on Your Site

Why CO₂ in the building matters

Combustion CO₂ and your concrete

Concrete is naturally alkaline, and that alkalinity is what keeps embedded rebar from rusting. When CO₂ concentrations in an enclosed space rise, the gas reacts with the concrete in a process called carbonation, lowering the pH from the exposed surface inward.

If the carbonation front reaches the rebar, the steel loses its protective environment and can begin to corrode. Rust expands, and expanding rust cracks concrete.

Open-flame heaters release their CO₂ directly into the space, right against fresh concrete, all season long. Indirect heat vents it outside instead.

EARLY STAGE carbonation zone (shallow) rebar protected by alkaline concrete exposed surface CARBONATION PROGRESSED carbonation zone reaches rebar rust forming on rebar exposed surface
Carbonation moves inward from the exposed surface. Once it reaches the rebar, corrosion can begin.

Drying a building this season?

Talk through the plan with us before heat season starts. Call 518-419-8688.